Meeting EMI requirements such as CISPR 25 and CISPR 32 is a key challenge in isolated power converter design. This presentation explores how transformer parasitics such as the interwinding capacitance and leakage inductance contribute to conducted and radiated emissions, with a focus on push-pull topologies.